- Help Center
- Pool & Spa Liquid Chlorine/Acid Feeders
- Stenner Pump General Information
-
Certified Pool Operator Class (CPO)
-
Coronavirus (COVID-19)
-
Engineering Data/Calculators
-
Pool Operation 101
-
Pool & Spa Chemical Controllers
-
Pool & Spa Boilers
-
Pool & Spa Heaters and Heat Pumps
-
Pool & Spa Calcium Hypochlorite Feeders
-
Pool & Spa Liquid Chlorine/Acid Feeders
-
Pool & Spa Salt Systems/Chlorine Generators
- ChlorKing ChlorSM Series
- ChlorKing ChlorPDS Multi-Pool Controller
- ChlorKing ChlorVFS Multi-Pool Controller
- ChlorKing ChlorVFSD Multi-Pool Controller
- ChlorKing Nexgen 60 Month Maintenance Schedule (All Models)
- ChlorKing Nexgen How-To Videos (All Models)
- ChlorKing Nexgen pH 10/10R
- ChlorKing Nexgen pH 20/40/60/80
- ChlorKing Nexgen pH 50/100
-
Pool & Spa Filters
-
Pool & Spa Filtration/Feature Pumps
-
Pool & Spa Water Chillers
-
SDS Sheets
-
UV Systems
-
VivoPoint Tutorial
-
Water Safety Month
How to Replace Tube on a Stenner Pump
Watch this video to learn how to replace a squeeze tube on a Stenner pump
In the video below you will see Stenner's recommended method of replacing the squeeze tube. If you do not have an adjustable pump the procedure still applies. Fixed rate pump users can skip the portion guiding users on setting the dial to 10.
NOTE: When reattaching lines do not use Teflon. The plastic feral is what seals the lines to the squeeze tube if Teflon is used leaks will occur.
Here is a fixed pump video
Stenner tubes should be changed every 6 months. If you wait until your tube is leaking it will cause corrosion inside your Stenner.
Steps:
- Remove Cover on bottom of stenner
- Flip cover to use at a tool to collapse roller assembly
- Rotate roller assembly counterclockwise to collapse roller
- Inspect clean and dry roller assembly, housing, and injector
- Install new tube and make sure to center on the roller assembly
- Add aquashield to pump head cover bushing
- Run 2 to 4 minutes before expanding rollers
- Insert latch into motor slot
- Use cover to expand rollers rotate clockwise
- Replace cover and reinstall